The lead line is a conductive in which circulates a very high frequency current. When the probe is in contact with the product, electronics detects a variation in the magnetic field around the probe and a reverse relay is then excited.
Technical Data :
DESIGNATION
CHARACTERISTICS
Power supply
110/230 VAC – 50Hz / 24/48 VAC – 50Hz
Casing
Cast aluminium
Protection
IP 65
Mounting
1’’ ¼Gaz
Working temperature
- 10°C à + 60°C max. 160°C with remote version
Output
Reverse relay
Consumption
21 mA
Cut-off capacity
10A – 250 VAC
Time delay adjustable
With 4 adjusting ranges between 0 and 3,5 minutes
Time delay and adjustments
By switch and potentiometers
Standard stainless probe length
220 mm / possibility of extension
(contact us for another lenght)
Main Advantages :
Stainless steel antenna or teflon part extension on demand.
Remote electronics for warm material detection maxi 160 °C.
Detection of sticky product
Easy to install
Casing in cast aluminium
Remote electronics (maximum distance between DRF and electronics is 2m)
Particularly suitable for sticky product, small particle size and low density.
News
20-23 April 2021, Bundaberg (Australia) :
ASSCT Industry equipment exhibition 2021, exhibitor and poster presentation.
September 29-30, 2021, Hotel Manaira, João Pessoa, Paraíba (Brazil) :
SEMTEC 7º Seminário Técnico da Indústria do Cimento e Cal